The Sensor Hub
The Microphone
Pricing
Software & Data Integrity
The MPK801 is engineered around the integrity of your data stream. Built-in packet-loss tracking means you always know your recording is complete, and heartbeat monitoring flags any microphone the moment it stops reporting - so nobody has to check by hand whether data is still arriving.
Heartbeat monitoring - a failed unit is identified by name the moment it stops reporting
Packet-loss tracking for verified, complete recordings
On-sensor calibration data, applied automatically. Swap a unit and keep measuring, with no recalibration and no model retraining
Linux audio driver (ALSA) - one input device, one channel per microphone, no per-device enumeration
A Windows driver and a Python API will be available at the end of 2026.
Applications
Cross-asset correlation
Build models that recognise when event B on machine 2 reliably follows event A on machine 1. Synchronization within 100 ns captures timing relationships across separate assets, not just within each one.
Cross-sensor validation to reduce false positives
Simultaneous, correlated readings from multiple positions confirm real events rather than firing on any one microphone's noise. Independent recordings cannot do this; synchronized ones can.
Spatially-diverse dataset generation
Capture the same acoustic event from multiple angles at the same instant. Richer training data than single-microphone datasets can produce, at a fraction of traditional multi-channel DAQ cost.
Specifications

RESONIKS MPK801 — key specifications | |
|---|---|
Frequency range | 20 Hz – 80 kHz, compensated to ±0.5 dB |
Acoustic Overload Point | 128 dB @ 10 % THD |
Sampling rate | Up to 192 kHz (bit depth scales with rate) |
Calibration | Stored on each sensor |
Unit-to-Unit consistency, compensated | ±0.5 dB |
Connection | Single M12 (data and power) via PEK481 Network Adapter |
OS Support | Linux only (Ubuntu 22.04+, Debian 12+) |
Dimensions | 75 × 36 × 22 mm, 140 g |
Housing | Aluminium, IP54 |
Operating temperature | −40 °C to 70 °C |
RESONIKS ARK141 Sensor Hub — key specifications | |
|---|---|
Sensors per hub | Up to 14 |
Sensor connections | 14× M12 |
Network | Ethernet |
Power input | 15–48 VDC, ≥30 W |
Dimensions | 230 × 75 × 38 mm, 800 g |
Synchronization accuracy | Within 100 ns |
Housing | Aluminium, IP54 |
Operating temperature | −40 °C to 50 °C |